Real time BARO-2nd MAP how to???
Read the manual to see if your question is answered there before posting. If you have questions about MS1/Extra or MS2/Extra or other non-B&G code configuration or tuning, please post them at http://www.msextra.com The full forum rules are here: Forum Rules, be sure to read them all regularly.
-
Joethemechanic
- MegaSquirt Newbie
- Posts: 22
- Joined: Sun May 09, 2004 1:51 pm
Real time BARO-2nd MAP how to???
Could someone point me in the right direction?
Thanks, Joe
To add an independent baro sensor to your MegaSquirt-II, use an MPX4250AP (the standard MS sensor). Run leads from:
sensor pin #1 (signal) to header position X7 on the MegaSquirt PCB through a 1K Ohm resistor,
sensor pin #2 to ground (the non-banded end of D1), and
sensor pin #3 to 5 Volts - use the via at the "M" in the copyright notice near the existing MAP sensor.
You can use other 0-5 volt pressure sensors, but you will have to calibrate it using the 'Tools/Sensor Calibration' dialog in MegaTune.
You can use the proto board (like i have done).
From what i've understood, the schematic (and port connection on the CPU) is the same as the msns-e.
So you can also get the schematic here:
http://megasquirt.sourceforge.net/extra ... ection.htm