How do you log knock?

Post by Clifton »

I'm running MSII, 2.36MT. I have a knocksense with it's output going to JS4. Is there something I need to turn on other than knock settings under sensor calibration? I didn't see anything in my log.
Bernard Fife
Super Squirter
Posts: 1009
Joined: Mon Feb 16, 2004 3:15 pm

Post by Bernard Fife »

Clifton,

At the end of the megasquirt-II.ini file, in the [Datalog] section, you need to add a line like this:

Code: Select all

  entry = knock,    "Knock", int,    "%d"
Any of the other values from the [Output Channels] section can be added to the datalog in a similar manner.

Lance.
Clifton
MegaSquirt Newbie
Posts: 33
Joined: Tue Aug 02, 2005 7:25 am

Post by Clifton »

Would this also allow me to use one of the gauges to view it in real time if I configure it in the ini file too?
Bernard Fife
Super Squirter
Posts: 1009
Joined: Mon Feb 16, 2004 3:15 pm

Post by Bernard Fife »

Clifton,

Yes, I believe so. Try it and let us know how it works.

Lance.
Clifton
MegaSquirt Newbie
Posts: 33
Joined: Tue Aug 02, 2005 7:25 am

Post by Clifton »

Thanks Lance. I'll let you know how it goes.