Knock sensing
Read the manual to see if your question is answered there before posting. If you have questions about MS1/Extra or MS2/Extra or other non-B&G code configuration or tuning, please post them at http://www.msextra.com The full forum rules are here: Forum Rules, be sure to read them all regularly.
Knock sensing
Is the microsquirt knock input ready to interpret a knock signal?
Does the knock sensor need an amplifier first?
Or is the input only for a retard signal?
Does code 2.890 even use the knock ability?
Re: Knock sensing
There has been a knock sense capability in the code for many years, way before 2.890 and it has remained throughout, including 3.4x code. Only the inital (red) microsquirt boards lacked the capability to see a knock signal (no pin to put it on), but on the V2.0 board a knock signal can be seen on AD7. However, there is no conditioning circuitry, only simple RC protection.800vtwin wrote:Looking for info on knock sensing. To start:
Is the microsquirt knock input ready to interpret a knock signal?
Yes the code has had knock sense capa
Does the knock sensor need an amplifier first?
Or is the input only for a retard signal?
Does code 2.890 even use the knock ability?
The code for knock sensing looks at the knock voltage, thresholds it, and applies retard/ no retard according to two strategies.
More on the code operation at http://www.megamanual.com/ms2/knock.htm