No tack input at startup, trigering off points

This forum is for discussing ignition setup, tuning, and troubleshooting for MicroSquirt (TM)
Forum rules
Read the manual to see if your question is answered there before posting. If you have questions about MS1/Extra or MS2/Extra or other non-B&G code configuration or tuning, please post them at http://www.msextra.com The full forum rules are here: Forum Rules, be sure to read them all regularly.
Post Reply
gvanhorn
MegaSquirt Newbie
Posts: 8
Joined: Sat Sep 04, 2010 4:46 pm

No tack input at startup, trigering off points

Post by gvanhorn »

Am trying to run MSD box from microsquirt, get good tack when reading off coil, but when set up to trigger off the points, get no INGOUT sig to fire coil. Coil is good, points good. Points are attached to 12 thru a 1k resistor. Opto + to points, Opto - to ground. Thing work great when just using the MSD. Is there a settting in code or something, doing everything in the manual. Help
gvanhorn
MegaSquirt Newbie
Posts: 8
Joined: Sat Sep 04, 2010 4:46 pm

Re: No tack input at startup, trigering off points

Post by gvanhorn »

Update--using o-scope have good sig from points to uS, on INGOUT I have a 5vdc pp pulse riding on a 5vref. so 5v to 10v pulse. I beleave it needs to go to 0v to charge coil. Is this a setting or is something bad?
mxrob
Helpful Squirter
Posts: 44
Joined: Thu Dec 24, 2009 5:43 pm
Location: Kentwood, MI
Contact:

Re: No tack input at startup, trigering off points

Post by mxrob »

I think you have to drop below something like 1.2 volts to get opto's hysteresis to switch. Have you verified your voltage pull down resistor set-up gets below this point with the points closed?
DR650 Dual Sport thumper µs FI success!
gvanhorn
MegaSquirt Newbie
Posts: 8
Joined: Sat Sep 04, 2010 4:46 pm

Re: No tack input at startup, trigering off points

Post by gvanhorn »

Iput on opto + is 0-8v, 0v when points closed, 8v when cranking points open, I should think this is enought to drive uS. Set up ing to run off MSD, all sensors reading good, hooked up ING1 to new coil -, put 12v on coil +, added wire from coil to sparkplug, grounded plug. With car running off MSD, got spark on plug, I get No spark on start up, only after car is running. So what is set up wrong or what is missing anyone ?
gvanhorn
MegaSquirt Newbie
Posts: 8
Joined: Sat Sep 04, 2010 4:46 pm

Re: No tack input at startup, trigering off points-Fixed!

Post by gvanhorn »

After conversation with Matt at DIY, found R20 open on board, replaced, car now running on uS. awaiting custom made twin injector Throttle body. :D
mxrob
Helpful Squirter
Posts: 44
Joined: Thu Dec 24, 2009 5:43 pm
Location: Kentwood, MI
Contact:

Re: No tack input at startup, trigering off points

Post by mxrob »

:D That's good news. After hours and hours of work it sure is nice to hear that engine fire up isn't it?
DR650 Dual Sport thumper µs FI success!