Microsquirt + GM TBI IAC

For discussing injector selection, manifold modifications, throttle bodies, fuel supply system design and construction, and FIdle valves and IACs.
Forum rules
Read the manual to see if your question is answered there before posting. If you have questions about MS1/Extra or MS2/Extra or other non-B&G code configuration or tuning, please post them at http://www.msextra.com The full forum rules are here: Forum Rules, be sure to read them all regularly.
Post Reply
jon volk
MegaSquirt Newbie
Posts: 6
Joined: Sun Nov 28, 2004 2:12 pm
Location: Milford, CT

Microsquirt + GM TBI IAC

Post by jon volk »

Planning out the wiring to run a GM TBI unit with Microsquirt. The TBI unit uses a 4 wire pintle iac valve and naturally the Microsquirt just features a single wire for a fast idle valve. Would it work to use the fi output to trigger a relay in which it would apply power to one iac coil to open it and when switched off switches power to the other coil making the iac valve act as an on/off deal?
Bernard Fife
Super Squirter
Posts: 1009
Joined: Mon Feb 16, 2004 3:15 pm

Re: Microsquirt + GM TBI IAC

Post by Bernard Fife »

jon,

That won't work. Stepper motors depend on the coils be energized in a specific pattern to move one way or the other. See: http://en.wikipedia.org/wiki/Stepper_motor

Someone may have made a PWM to stepper driver circuit/PCB, though I can't recall off the top of my head.

Lance.