The MegaSquirt Project has experienced explosive growth other the years, with hundreds of new MS installations occurring every week - a phenomenal success! MegaSquirt has been successfully used in all aspects of Internal Combustion engine applications including R&D, Industry, Race, and Research. The MS project has transformed itself from a simple R&D project into a full-featured mature engine control system. To reflect this the support structure has also changed to meet the needs of MegaSquirt Users.
Moving forward, the R&D forums for MegaSquirt project are in a read-only mode - no new forum posts are accepted.
However the forums will remain available for view, they still contain a wealth of information on how MegaSquirt works, how it is installed and used. Feel free to search the forums for information, facts, and overview. While the R&D forum traffic has slowed in recent years, this is not at all a reflection of Megasquirt users, which continue to grow year after year. What has changed is that the method of MegaSquirt support today has rapidly moved to Facebook, this is where the vast majority of interaction is happening now. For those not on Facebook the msextra forums is another place for product support. Finally, for product selection assistance, all of the MegaSquirt vendors are there to help you select a system, along with all of the required pieces to make it complete.
This forum is for discussion of MicroSquirt (TM) from Bowling and Grippo. The MicroSquirt information site is at www.usEasyDocs.com
Forum rules
Read the manual to see if your question is answered there before posting. If you have questions about MS1/Extra or MS2/Extra or other non-B&G code configuration or tuning, please post them at http://www.msextra.com The full forum rules are here: Forum Rules, be sure to read them all regularly.
I feel like a fine fellow having to ask this question, but I am having a hard time trying to figure out the spare outputs that became available with the new firmware. I am wanting to trigger a relay for water injection and a shift light. Looking at the spare output documentation, it looks like the IAC pins would work great for this, since they can supply enough current to trigger a relay. From what I gathered, you change the setting for the IAC control to being on, but set everything to zero so it doesn't change. I have done this and am not getting anything out of any of the IAC pins. Is there something that needs jumpered inside of the megasquirt, or something that needed to be done differently when it was built? Any help would be greatly appriciated. Thanks!
-jeremy-
Thanks a ton, but if I hadn't already read all that, I wouldn't be posting questions. I have followed all the instructions on that page but am still having problems. I would like to use the IAC outputs since they can directly control a relay. I am not getting any voltage output from any of the IAC wires when I try and set up the spare outputs. Any ideas why this isnt' working?
-jeremy-
No, I didn't install that jumper. Now that you mention it though, it jumps right out of the text at me. So I should just be able to install the jumper and go from there. Can I use just the one power wire and not the ground wire? It would be easier to chassis ground the other side of the relay. Thanks.
-jeremy-
i was wondering the same thing about which two of the four to use, and grounding, but upon re-reading the spare.htm page, it appears that it doesnt matter which from each pair you choose, just that one will be inverted. so on might be off. grounding outside should be fine.
zguy360 wrote:Has no one hooked up the spare outputs for the Megasquirt II v3 with the new 2.33 firmware?
I use the FIDLE for my electric fan relays (switches negative on 2 relays) and the Knock Enable port (jumpered to SPR3 from memory on the DB37) to give 5V to my HEI 7pin module when RPM > 350.
I'll be using an IAC stepper so I can't tell you how those spare ports work. I have had no issues to date with either FIDLE or Knock ports in my configuration.